Register free!
Search
 
     

Click for Weather
  #1  
Old 12-04-2012, 09:44 PM
chevyzrule810's Avatar
chevyzrule810 chevyzrule810 is offline
Senior Member
 
Join Date: Oct 2010
Location: Northeast
Posts: 859
Can it work

Can an sehp cable operated pump be converted to run hydraulic?
__________________
2006 Silverado 2500HD
8" Fisher HD Minute Mount 2
Reply With Quote
  #2  
Old 12-04-2012, 10:12 PM
Morrissey snow removal's Avatar
Morrissey snow removal Morrissey snow removal is offline
PlowSite.com Addict
 
Join Date: Sep 2006
Location: lunenburg, ma
Posts: 1,800
what do u mean?
__________________
Ford Trucks
Fisher Plows
ice o way Sanders
Caterpillar Equipment
Reply With Quote
  #3  
Old 12-05-2012, 08:21 AM
chevyzrule810's Avatar
chevyzrule810 chevyzrule810 is offline
Senior Member
 
Join Date: Oct 2010
Location: Northeast
Posts: 859
Can you take a cable operated sehp pump and make it so that it is an electric pump like a mm1 or mm2
__________________
2006 Silverado 2500HD
8" Fisher HD Minute Mount 2
Reply With Quote
  #4  
Old 12-05-2012, 09:35 AM
Morrissey snow removal's Avatar
Morrissey snow removal Morrissey snow removal is offline
PlowSite.com Addict
 
Join Date: Sep 2006
Location: lunenburg, ma
Posts: 1,800
i think so but u have to change the vavle body to a sehp instead of the cehp cable style
__________________
Ford Trucks
Fisher Plows
ice o way Sanders
Caterpillar Equipment
Reply With Quote
  #5  
Old 12-06-2012, 06:58 PM
sweetk30's Avatar
sweetk30 sweetk30 is offline
PlowSite.com Addict
 
Join Date: Sep 2006
Location: horseheads,ny 14845
Posts: 1,589
unbolt cable box /valve combo and bolt up electric parts and wire it up.

and fyi western pumps share a lot of these parts but were just shorter lift ram and painted red.
__________________


79k30/fisher speedcaster live hydro with 8ft&9ft blades/tbi350/th400kcase/205/dana60/posi14ff/flatbed/dump/6"lift/35x12.50x16.5 general grabber m/t tires on western wheel slots/federal signal streethawk all light bar
Reply With Quote
  #6  
Old 12-06-2012, 09:50 PM
RepoMan207's Avatar
RepoMan207 RepoMan207 is offline
2000 Club Member
 
Join Date: Oct 2008
Location: Maine
Posts: 4,948
Quote:
Originally Posted by sweetk30 View Post
unbolt cable box /valve combo and bolt up electric parts and wire it up.

and fyi western pumps share a lot of these parts but were just shorter lift ram and painted red.
Hey Sweet, it's been awhile. That's not entirely true..Fisher also used the shorter EHP's SEHP's. Other then color...they're all the same.

To the OP....I'm not 100% sure on this because I've never tried to convert them, however, with that being said, I've done countless tear downs on the EHP & SEHP pumps, I've even had the chance to do some side by side. I can tell you first hand, the castings on the reservoirs are not the same. I'm all but postive, that it can't be done. Now, there is nothing that says that you can't find a used SEHP (There are plenty out there), and simply exchange it for the EHP.
__________________
Ryan
Hodge's Snow & Ice Management LLC
Windham, ME
PlowGuy.Net




Reply With Quote
  #7  
Old 12-07-2012, 07:05 AM
chevyzrule810's Avatar
chevyzrule810 chevyzrule810 is offline
Senior Member
 
Join Date: Oct 2010
Location: Northeast
Posts: 859
I found a cable operated pump without a motor for short money.I'm just trying to figure out if its worth it to buy it,convert it and put a motor on it.Here is a picture of it.Its the silver one in the other is a western.
Attached Images
   
__________________
2006 Silverado 2500HD
8" Fisher HD Minute Mount 2
Reply With Quote
  #8  
Old 12-07-2012, 08:34 AM
RepoMan207's Avatar
RepoMan207 RepoMan207 is offline
2000 Club Member
 
Join Date: Oct 2008
Location: Maine
Posts: 4,948
Quote:
Originally Posted by chevyzrule810 View Post
I found a cable operated pump without a motor for short money.I'm just trying to figure out if its worth it to buy it,convert it and put a motor on it.Here is a picture of it.Its the silver one in the other is a western.
Both of those are EHP's, you can't put a Solenoid Valve body on those casting....

This is a SEHP...notice the difference.?.?

__________________
Ryan
Hodge's Snow & Ice Management LLC
Windham, ME
PlowGuy.Net




Reply With Quote
  #9  
Old 12-07-2012, 09:08 AM
chevyzrule810's Avatar
chevyzrule810 chevyzrule810 is offline
Senior Member
 
Join Date: Oct 2010
Location: Northeast
Posts: 859
now I see it yes.Ok it was worth a shot an extra pump for a spare.Thanks guys
__________________
2006 Silverado 2500HD
8" Fisher HD Minute Mount 2
Reply With Quote
  #10  
Old 12-07-2012, 09:18 AM
RepoMan207's Avatar
RepoMan207 RepoMan207 is offline
2000 Club Member
 
Join Date: Oct 2008
Location: Maine
Posts: 4,948
Absolutely. I'm looking to swap a friends old setup over myself...but where it's a charity deal, I'm not looking to spend alot. If you swap over, and your controller for the EHP is good, I would consider buying it off you. I'm all but positive that's his biggest issue right now. Keep me in mind if you get to that point.
__________________
Ryan
Hodge's Snow & Ice Management LLC
Windham, ME
PlowGuy.Net




Reply With Quote
  #11  
Old 12-07-2012, 08:46 PM
sweetk30's Avatar
sweetk30 sweetk30 is offline
PlowSite.com Addict
 
Join Date: Sep 2006
Location: horseheads,ny 14845
Posts: 1,589
i stand corrected .

pics make it 100% clear.
__________________


79k30/fisher speedcaster live hydro with 8ft&9ft blades/tbi350/th400kcase/205/dana60/posi14ff/flatbed/dump/6"lift/35x12.50x16.5 general grabber m/t tires on western wheel slots/federal signal streethawk all light bar
Reply With Quote
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump




Powered by vBulletin® Version 3.8.6
Copyright ©2000 - 2014, Jelsoft Enterprises Ltd.
Copyright ©2000 - 2012 PlowSite.comô Moose River Media
All times are GMT -5. The time now is 05:39 AM.

Page generated in 0.03830 seconds with 10 queries